Skip to main content

Acute thrombosis in mitralic mechanical prosthesis: a case report

Abstract

We describe a case of a man, 42 years old, submitted to successful fibrinolitic strategy with rTPA in acute mitralic prosthesis valve thrombosis and ipomobility of one emidisk. There aren't a consensus agreement in therapeutic strategy but we may support the approach of some authors that employ fibrinolisis in patients without absolute or relative controindications and if thrombus dimension is less than 1 cm otherwise they make use of heparin therapy in non obstructive thrombosis with successive transesophageal echocardiography evaluation for the efficacy and the later indication for thrombolisis or surgery treatment.

Introduction

The high incidence (7–34%/year) of thromboembolic risk in patients with valvular prosthesis without a correct administration of anticoagulant therapy has been demonstrated since the last 40 years. This risk is higher in patients older than 50 years old, with spherical prosthesis (actually not yet used), with prosthesis in mitralic location and in patients with association of atrial fibrillation [1–5]. However mechanical prosthesis have a long last and are more functional safely compared with the biological one; so mechanical devices are preferable implanted in young people even if they need a correct anticoagulation.

So some authors propose, as gold standard for oral anticoagulant therapy, to maintain INR (international normalized ratio) value between 2 and 3 (or 2.5–3.5) in all patients, between 3 and 4.5 in patients with old caged prosthesis and in association with antiplatlet therapy (ASA 100 mg) in patients with double prosthesis, ball devices, prosthetic valved conduit, patients with coronarosclerosis or by coronary artery bypass grafts in order to reduce thromboembolic risk [6].

Case presentation

We describe a case of a man, 42 years old, that became to our emergency room for dyspnoea and tachycardia with fever (37.5°C) since two days with signs of congestive heart failure (pulmonary rantoli without ascites and pedal oedema).

The patient was carrier of a mitralic mechanical emidisc prosthesis (Sorin n°31 Bicarbon), implanted 7 years ago for mixomatosus valve with severe mitralic insufficiency from LA e LP mitral valve prolapse. The patient referred a lack in anticoagulant therapy with dicumarolic drug for about one week.

The electrocardiogram showed sinusal tachycardia (138 bpm) and left anterior bundle brunch emiblock.

Laboratory results demonstrated leukocytosis (17,5 × 1000/ul), inadequate values of scoagulation (INR 1.2, PT 13.1 sec, PT 98%), D-Dimer 569 ng/ml.

Chest radiograph described signs of pulmonary congestion. So the patients was treated with diuretics, inotropic agents at kidneys dosage and antibiotic e.v.

The transthoracic echocardiogram color Doppler showed a mechanical prosthesis in mitralic position with ipomobility of one emidisc and a transoesophageal one confirmed the presence of a thrombus on the atrial side, left atrial enlargement, trans prosthesis gradient major than 30 mmHg and medium 28 mmHg (fig. 1, 2, 3)

Figure 1
figure 1

Transesophageal echocardiography: Doppler CW on mitral prosthesis valve with the evidence of transvalvular gradient.

Figure 2
figure 2

Transesophageal echocardiography: 2D evidence of mitral prosthesis valve thrombosis.

Figure 3
figure 3

Transesophageal echocardiography: 2D evidence of mitral prosthesis valve thrombosis.

In consideration of these reports the patient started a treatment with not fractionated heparin e.v. and fibrinolisis (rTPA) with improved in symptoms and hemodynamic signs. An echocardiogram color Doppler carried out after thrombolisis showed a marked reduction in transvalvular prosthetic gradient (ΔP medium 5 mmHg) confirmed by a transoesophageal echocardiography (fig. 4) that pointed out a resolution of the thrombotic image but evidenced the presence of two filaments moving towards the atrial side.

Figure 4
figure 4

Transesophageal echocardiography post fibrinolysis: CW on mitral prosthesis valve. Significative reduction of transvalvular gradient.

The patients started with oral anticoagulant therapy in association with the not fractioned heparin e.v until the achieved objective of an adequate anticoagulant value (INR between 2.5 and 3.5). after 10 days another echocardiogram color Doppler was performed with the evidence of complete resolution of prosthetic thrombosis.

Discussion

Prosthetic thrombosis is a frightened complication of mechanical mitralic valve especially if there is a lack in the anticoagulant therapy.

The incidence of thrombosis in mechanical valve (and also in biological one) is between 0.1 and 5.7% pts/year in patients with uncorrected anticoagulant therapy [1–4].

The role of transesophageal echocardiography is essential to distinguish malfunctioning due to prosthesis obstruction or to prosthetic thrombosis with ipomobility of the mobile elements or thrombosis with preserved mobile elements excursion [7–10].

The prevalence of pannus formation in patients reoperated for prosthesis malfunction is about 25% and this anatomical evidence explain the vulnerability to thrombosis.

Medical and surgery strategy are the two possible options to treatment for acute thrombosis in prosthesis device [11–13].

Mortality percentage during surgery for prosthetic thrombosis is till 60% (in unstable hemodinamic patients and in emergency) while fibrinolitic agents involve a percentage of embolic complication between 9 and 15% with recurrent thrombosis in 16% of cases.

Active blooding, hemorrhagic stroke, recent skull trauma and uncontrolled high blood pressure are absolute controindications to fibrinolitic treatment; endocarditic processes, intracardiac large thrombus and recent surgery major operation or trauma are relative contraindication to thrombolisis [11–14].

Adequate treatment choice is related with clinical status (NYHA class), thrombus dimension, symptoms duration, prosthesis type (one disk versus bileaflets), elements ipomobility versus immobility and evidence of endocarditic process with abscess and thrombosis.

In our case we report the successful fibrinolitic strategy with rTPA in a patients with acute mitralic prosthesis valve thrombosis and ipomobility of one emidisk such as demonstrated in some study in patients with bidisk valve prosthesis: standard indications to thrombolisis in acute thrombosis are recent thrombus formation and only one disk blocked.

Surgery strategy is indicated in endocarditic process with abscess and large dimensions thrombus or in old date thrombus formation and if two disks prosthesis are involved.

In conclusion we could affirm that there aren't a consensus agreement in therapeutic strategy but we may support the approach of some authors that employ fibrinolisis in patients without absolute or relative controindications and if thrombus dimension is less than 1 cm otherwise they make use of heparin therapy in non obstructive thrombosis with successive transesophageal echocardiography evaluation for the efficacy and the later indication for thrombolisis or surgery treatment.

Surgery strategy should be reserved to patents with thrombus major than 1 cm, with or without endocarditis or in patients with controindications to thrombolisis.

Consent

Written informed consent was obtained from the patient for publication of this case report and accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

References

  1. Tang GH, Rao V, Siu S, Butany J: Thrombosis of mechanical mitral valve prosthesis. J Card Surg. 2005, 20 (5): 481-6. 10.1111/j.1540-8191.2005.200474.x.

    Article  PubMed  Google Scholar 

  2. Badano LP, Oikonomou KA, Fioretti PM: Acute thrombosis of mechanical mitral valve prosthesis: Echo-doppler diagnosis and succesfull treatment with systemic thrombolisis. Eur J Echocardiography. 2003, 4: 73-75. 10.1053/euje.2002.0614.

    Article  CAS  Google Scholar 

  3. Cokkinos P, Koutrouli E, Chronidou F, Kremastinos DT: Acute Thrombosis of a prosthetic mitral valve. Eur J Echocardiogr. 2005, 6 (6): 405-6. 10.1016/j.euje.2005.07.015.

    Article  PubMed  Google Scholar 

  4. Bottio T, Gerosa G, Basso C, Thiene G, Casarotto DC: Unexpected mechanical bileaflet valve thrombosis in mitral position: what is better to do, re-replacement or thrombolysis. Langenbeck's Arch Surg. 2002, 387: 166-69. 10.1007/s00423-002-0302-1.

    Article  CAS  Google Scholar 

  5. Martinel J, Jiminez A, Rabago G, Artiz V, Fraile J, Farrè J: Mechanical cardiac valve thrombosis: is thrombectomy justified?. Circulation. 1991, 84 (suppl III): 70-75.

    Google Scholar 

  6. Pengo V, Prisco S, Iliceto Gestione S: attuale della terapia anticoagulante orale. Ital Heart J suppl. 2002, 3 (5): 502-517.

    PubMed  Google Scholar 

  7. Lus P, Giacomin A, Cavarzarani A, Valfrè C: Detection of acute thrombosis of mitral tilting disk prosthesis by transesophageal echocardiography. Int J Card Imaging. 1994, 10 (4): 305-308. 10.1007/BF01137722.

    Article  Google Scholar 

  8. Aoyagi S, Fukunaga S, Suzuki S, Nishi Y, Oryoji A, Kosuga K: Obstruction of mechanical valve prosthesis: clinical diagnosis and surgical or non surgical treatment. Surgery Today. 1996, 26 (6): 400-406. 10.1007/BF00311926.

    Article  CAS  PubMed  Google Scholar 

  9. Gillham MJ, Tousignant CP: Diagnosis by intraoperative transesophageal echocardiography of acute thrombosis of mechanical aortic valve prosthesis associated with the use of biological glue. Anesth Analg. 2001, 92: 1023-5.

    Google Scholar 

  10. Caso P, De Simone L, Severino S: Protesi valvolari cardiache: valutazione ecocardiografica. Ital Heart J. 2002, 3 (suppl 3): 17S-22S.

    Google Scholar 

  11. Silber H, Khan SS, Matloff JM, Chaux A, De Robertis M, Gray R: The St. Jude valve: thrombolysis as the first line terapy for cardiac valve thrombosis. Circulation. 1993, 87: 30-7.

    Article  CAS  PubMed  Google Scholar 

  12. Vitale N, Renzulli A, Agozzino L, Pollice A, Tedesco N, de Luca Tupputi Schinosa L, Cotrufo M: Obstruction of mechanical mitral prosthesis: analysis of patologic findings. Ann Thorac Surg. 1997, 63: 1101-1106. 10.1016/S0003-4975(96)01391-4.

    Article  CAS  PubMed  Google Scholar 

  13. Rizzoli G, Guglielmi C, Toscano G, Pistorio V, Vendramin I, Bottio T, Thiene G, Casarotto D: Reoperation for acute prosthetic thrombosis and pannus: an assesment of rates, relationship and risk. Eur J Cardiothorac Surg. 1999, 16: 74-80. 10.1016/S1010-7940(99)00124-4.

    Article  CAS  PubMed  Google Scholar 

  14. Bollag L, Attenhofer CH, Vogt PR: Symptomatic mechanical heart valve thrombosis: high morbility and mortality despite succesfull treatment options. Swiss Med Wkly. 2001, 131: 109-116.

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Enrico Vizzardi.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

AD and EC performed transthoracic and thransesophageal echocardiography.

EV, GZ and EA treated and followed up the patient during the admission and the stay in the hospital. LDC gave us the supervision.

Authors’ original submitted files for images

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Vizzardi, E., D'Aloia, A., Zanini, G. et al. Acute thrombosis in mitralic mechanical prosthesis: a case report. Cases Journal 2, 30 (2009). https://doi.org/10.1186/1757-1626-2-30

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1757-1626-2-30

Keywords